Industrial Plug & Socket Coupling
|
Earth contact position
Rated current(A)
|
Pole
|
4h
|
63
|
125
|
3
|
Dimension(mm)
|
a
|
62
|
80
|
b
|
68
|
96
|
c
|
47
|
60
|
d
|
48
|
70
|
e
|
36
|
42
|
f
|
37
|
43
|
g
|
55
|
75
|
Cable nominal
cross-section area(mm2)
|
1-2.5
|
2.5-6
|
|
|
HJ-313-4/HJ-323-4
Current(A):16A,32A
Voltage(V):110-130V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
63
|
125
|
3
|
Dimension(mm)
|
a
|
62
|
80
|
b
|
68
|
96
|
c
|
47
|
60
|
d
|
48
|
70
|
e
|
36
|
42
|
f
|
37
|
43
|
g
|
55
|
75
|
Cable nominal
cross-section area(mm2)
|
1-2.5
|
2.5-6
|
|
|
HJ-313/HJ-323
Current(A):16A,32A
Voltage(V):220-240V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
63
|
125
|
4
|
Dimension(mm)
|
a
|
76
|
80
|
b
|
86
|
96
|
c
|
60
|
60
|
d
|
61
|
70
|
e
|
47
|
42
|
f
|
37
|
43
|
g
|
64
|
75
|
Cable nominal
cross-section area(mm2)
|
1-2.5
|
2.5-6
|
|
|
HJ-314/HJ-324
Current(A):16A,32A
Voltage(V):380-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
63
|
125
|
5
|
Dimension(mm)
|
a
|
76
|
82
|
b
|
86
|
97
|
c
|
60
|
60
|
d
|
61
|
70
|
e
|
47
|
42
|
f
|
37
|
47
|
g
|
72
|
81
|
Cable nominal
cross-section area(mm2)
|
1-2.5
|
2.5-6
|
|
|
HJ-315/HJ-325
Current(A):16A,32A
Voltage(V):220-380V~
240-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
63
|
125
|
3
|
Dimension(mm)
|
a
|
100
|
120
|
b
|
113
|
130
|
c
|
80
|
100
|
d
|
92
|
108
|
e
|
73
|
92
|
f
|
78
|
96
|
g
|
90
|
102
|
h
|
124
|
135
|
i
|
6
|
6
|
Cable nominal
cross-section area(mm2)
|
6-25
|
25-70
|
|
|
HJ-333/HJ-343
Current(A):63A,125A
Voltage(V):220-240V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
63
|
125
|
3
|
Dimension(mm)
|
a
|
100
|
120
|
b
|
113
|
130
|
c
|
80
|
100
|
d
|
92
|
108
|
e
|
73
|
92
|
f
|
78
|
96
|
g
|
90
|
102
|
h
|
124
|
135
|
i
|
6
|
6
|
Cable nominal
cross-section area(mm2)
|
6-25
|
25-70
|
|
|
HJ-334/HJ-344
Current(A):63A,125A
Voltage(V):380-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
63
|
125
|
5
|
Dimension(mm)
|
a
|
100
|
120
|
b
|
113
|
130
|
c
|
80
|
100
|
d
|
92
|
108
|
e
|
73
|
92
|
f
|
78
|
96
|
g
|
90
|
102
|
h
|
124
|
135
|
i
|
6
|
6
|
Cable nominal
cross-section area(mm2)
|
6-25
|
25-70
|
|
|
HJ-335/HJ-345
Current(A):63A,125A
Voltage(V):220-380V~
240-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
63
|
125
|
3
|
Dimension(mm)
|
a
|
100
|
120
|
b
|
113
|
130
|
c
|
80
|
100
|
d
|
92
|
108
|
e
|
73
|
92
|
f
|
78
|
96
|
g
|
90
|
102
|
h
|
124
|
135
|
i
|
6
|
6
|
Cable nominal
cross-section area(mm2)
|
6-25
|
25-70
|
|
|
HJ-3332/HJ-3432
Current(A):63A,125A
Voltage(V):220-240V~
Protection degree:IP67
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
63
|
125
|
4
|
Dimension(mm)
|
a
|
100
|
120
|
b
|
113
|
130
|
c
|
80
|
100
|
d
|
92
|
108
|
e
|
73
|
92
|
f
|
78
|
96
|
g
|
90
|
102
|
h
|
124
|
135
|
i
|
6
|
6
|
Cable nominal
cross-section area(mm2)
|
6-25
|
25-70
|
|
|
HJ-3342/HJ-3442
Current(A):63A,125A
Voltage(V):380-415V~
Protection degree:IP67
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
63
|
125
|
5
|
Dimension(mm)
|
a
|
100
|
120
|
b
|
113
|
130
|
c
|
80
|
100
|
d
|
92
|
108
|
e
|
73
|
92
|
f
|
78
|
96
|
g
|
90
|
102
|
h
|
124
|
135
|
i
|
6
|
6
|
Cable nominal
cross-section area(mm2)
|
6-25
|
25-70
|
|
|
HJ-3352/HJ-3452
Current(A):63A,125A
Voltage(V):220-380V~
240-415V~
Protection degree:IP67
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
4h
|
16
|
32
|
3
|
Dimension(mm)
|
a
|
69.5
|
71
|
b
|
69.5
|
71
|
c
|
56
|
56
|
d
|
56
|
56
|
e
|
28
|
28
|
f
|
48
|
63
|
g
|
70
|
88
|
i
|
52
|
56
|
Cable nominal
cross-section area(mm2)
|
1-2.5
|
2.5-6
|
|
|
HJ-413-4/HJ-423-4
Current(A):16A,32A
Voltage(V):110-130V~
Protection degree:IP44
|
|
|
|
|
|